Home
P9494-UL
P.O. Box 24, Bay Head, New Jersey 08742, 732-892-8989, FAX: 509-275-5820
LOW DENSITY HMW-PE PAIGE TRACER UL-LISTED 30V or 600V FOR GAS PIPELINES/ WATER PIPELINES & FIBER OPTIC LINES INSULATION: POLYETHYLENE SIZES: 14-8 AWG CONDUCTOR: SOLID OR STRANDED BARE ANNEALED COPPER
®
1.0 DESCRIPTION:
Single conductor solid or strand- ed, bare annealed copper, low density high molecular weight Polyethylene insulation.
2.0 APPLICATION:
Outstanding dielectric strength, moisture resistance and low capacitance of the high molec- ular weight Polyethylene, cou- pled with its high resistance to corrosive chemicals, makes this the optimum Tracer Wire for locating buried Utilities. Polyethylene is resistant to salt water and most organic and inorganic substances. A.P.W.A. Color Code: Gas-Yellow, Water- Blue, Fiber-Orange.
3.0 TEMPERATURE RATING
-55°C +60°C
4.0 CONSTRUCTION DATA
HMW-PE
UL 600VCONSTRUCTION SIZE INSULATION WEIGHT
(AWG) THICKNESS (LB/1000)
14 45MILS 20
12 45MILS 29
10 45MILS 42
8 45MILS 80
UL 30VCONSTRUCTION SIZE INSULATION WEIGHT
(AWG) THICKNESS (LB/1000)
14 30MILS 18
12 30MILS 25
10 30MILS 38
8 30MILS 75
FOR SPLICING – 3M DBY’S/DBR’S ARE RECOMMENDED OR PAIGE DBM’S. CUSTOMPUTUPSANDSURFACEPRINTAVAILABLE. FIRMORFLOATPRICING/BLANKETORDERS/DROPSHIPS. CALL BILL GAAL AT 732-892-8989 OR FAX YOUR INQUIRIES TO 732-892-0606 FOR PRICING INFORMATION.